Detail DSE 4520CC ( DEEP SEA 4520CC )

DSE4510/20

AUTO START AND AUTO MAINS FAILURE

CONTROL MODULES

(ALTERNATOR FREQUENCY & CAN SPEED SENSING)

 

The DSE4510 Auto Start Control

Module and the DSE4520 Auto

Mains (Utility) Failure Control

Module are suitable for a wide

variety of single gen-set

applications.

Whilst maintaining functions

included within higher end

controllers, such as generator or

load power monitoring, the

DSE45xx range of especially

compact controllers provide the

user with the ultimate size to

feature ratio.

Monitoring engine speed, oil

pressure, coolant temperature,

frequency, voltage, current, power

and fuel level, the modules will give

comprehensive engine and

alternator protection. This will be

indicated on the largest back-lit

LCD icon display in its class via an

array of warning, electrical trip and

shutdown alarms.

Electronic J1939 (CAN) and nonelectronic

(alternator frequency

sensing) engine support for diesel,

gas and petrol engines all in one

variant. With a number of flexible

inputs, outputs and protections, the

module can be easily adapted to

suit a wide range of applications.

Through USB Communication both

modules can be easily configured

using the DSE Configuration Suite

PC Software or can be fully

configured through the module's

front panel editor.

All DSE products are supported by

the DSE global tech nical support

team which gives our customers

and end users access to 24 hour

system help and advice.

 

KEY BENEFITS

• Ultimate size to feature ratio

• Automatically transfers between

mains (utility) and generator

(DSE4520 only)

• Hours counter provides accurate

information for monitoring and

maintenance periods

• User-friendly set-up and button

layout for ease of use

• Multiple parameters are

monitored simultaneously which

are clearly displayed on the

largest back-lit icon display in

its class

• The module can be configured

to suit a wide range of

applications

• Uses DSE Configuration Suite

PC Software for simplified

configuration

• Compatible with a wide range

of CAN engines

• Licence-free PC software

• IP65 rating (with optional

gasket) offers increased

resistance to water ingress

 

KEY FEATURES

• Alternator frequency & CAN

speed sensing in one variant

• Largest back-lit icon display in

its class

• Heated display option

• Real time clock provides

accurate event logging

• Fully configurable via the fascia

or PC using USB

communication

• Extremely efficient power save

mode

• 3 phase generator sensing

• 3 phase mains (utility) sensing

(DSE4520 only)

• Compatible with 600 V ph to ph

nominal systems

• Generator/load power

monitoring (kW, kV A, kV Ar, pf)

• Accumulated power monitoring

(kW h, kVA h, kVAr h)

• Generator overload protection

(kW)

• Generator/load current

monitoring and protection

• Fuel and start outputs

(configurable when using CAN)

• 4 configurable DC outputs (2 for

DSE4510)

• 3 configurable analogue/digital

inputs

• 4 configurable digital inputs

• Configurable staged loading

outputs

• 3 engine maintainance alarms

• Engine speed protection

• Engine hours counter

• Engine pre-heat

• Engine run-time scheduler

• Engine idle control for starting &

stopping

• Battery voltage monitoring

• Start on low battery voltage

• Configurable remote start input

• 1 alternative configuration

• Comprehensive warning,

electrical trip or shutdown

protection upon fault condition

• LCD alarm indication

• Event log (50)

 

SPECIFICATION

DC SUPPLY

CONTINUOUS VOLTAGE RATING

8 V to 35 V Continuous

CRANKING DROPOUTS

Able to survive 0 V for 50 mS, providing

supply was at least 10 V before dropout and

supply recovers to 5 V. This is achieved

without the need for internal batteries.

LEDs and backlight will not be maintained

during cranking.

MAXIMUM OPERATING CURRENT

85 mA at 12 V, 96 mA at 24 V

MAXIMUM STANDBY CURRENT

51 mA at 12 V, 47 mA at 24 V

MAXIMUM SLEEP CURRENT

35 mA at 12 V, 32 mA at 24 V

MAXIMUM DEEP SLEEP CURRENT

<10 uA at 12 V, <10 uA at 24 V

MAINS (UTILITY) DSE4520 ONLY

VOLTAGE RANGE

15 V to 415 V AC (Ph to N)

26 V to 719 V AC (Ph to Ph)

FREQUENCY RANGE

3.5 Hz to 75 Hz

OUTPUTS

OUTPUT A (FUEL)

10 A short term, 5 A continuous,

at supply voltage

OUTPUT B (START)

10 A short term, 5 A continuous,

at supply voltage

AUXILIARY OUTPUTS C & D

2 A DC at supply voltage

AUXILIARY OUTPUTS E & F DSE4520

2 A DC at supply voltage

GENERATOR

VOLTAGE RANGE

15 V to 415 V AC (Ph to N)

26 V to 719 V AC (Ph to Ph)

FREQUENCY RANGE

3.5 Hz to 75 Hz

DIMENSIONS

OVERALL

140 mm x 113 mm x 43 mm

5.5’’ x 4.4” x 1.7”

PANEL CUT-OUT

118 mm x 92 mm

4.6’’ x 3.6”

MAXIMUM PANEL THICKNESS

8 mm

0.3”

STORAGE TEMPERATURE RANGE

-40 °C to +85 °C

-40 °F to +185 °F

OPERATING TEMPERATURE RANGE

-30 °C to +70 °C

-22 °F to +158 °F

-40 °C to +70 °C (for heated display variant)

-40 °F to +158 °F (for heated display variant)

 

ENVIRONMENTAL TESTING STANDARDS

ELECTRO-MAGNETIC COMPATIBILITY

BS EN 61000-6-2

EMC Generic Immunity Standard for

the Industrial Environment

BS EN 61000-6-4

EMC Generic Emission Standard for

the Industrial Environment

ELECTRICAL SAFETY

BS EN 60950

Safety of Information Technology Equipment,

including Electrical Business Equipment

TEMPERATURE

BS EN 60068-2-1

Ab/Ae Cold Test -30 oC

BS EN 60068-2-2

Bb/Be Dry Heat +70 oC

VIBRATION

BS EN 60068-2-6

Ten sweeps in each of three

major axes

5 Hz to 8 Hz at +/-7.5 mm,

8 Hz to 500 Hz at 2 gn

HUMIDITY

BS EN 60068-2-30

Db Damp Heat Cyclic 20/55 oC

at 95% RH 48 Hours

BS EN 60068-2-78

Cab Damp Heat Static 40 oC

at 93% RH 48 Hours

SHOCK

BS EN 60068-2-27

Three shocks in each of three major axes

15 gn in 11 mS

DEGREES OF PROTECTION

PROVIDED BY ENCLOSURES

BS EN 60529

IP65 - Front of module when installed into the

control panel with the optional sealing gasket.