DSE4510/20
AUTO START AND AUTO MAINS FAILURE
CONTROL MODULES
(ALTERNATOR FREQUENCY & CAN SPEED SENSING)
The DSE4510 Auto Start Control
Module and the DSE4520 Auto
Mains (Utility) Failure Control
Module are suitable for a wide
variety of single gen-set
applications.
Whilst maintaining functions
included within higher end
controllers, such as generator or
load power monitoring, the
DSE45xx range of especially
compact controllers provide the
user with the ultimate size to
feature ratio.
Monitoring engine speed, oil
pressure, coolant temperature,
frequency, voltage, current, power
and fuel level, the modules will give
comprehensive engine and
alternator protection. This will be
indicated on the largest back-lit
LCD icon display in its class via an
array of warning, electrical trip and
shutdown alarms.
Electronic J1939 (CAN) and nonelectronic
(alternator frequency
sensing) engine support for diesel,
gas and petrol engines all in one
variant. With a number of flexible
inputs, outputs and protections, the
module can be easily adapted to
suit a wide range of applications.
Through USB Communication both
modules can be easily configured
using the DSE Configuration Suite
PC Software or can be fully
configured through the module's
front panel editor.
All DSE products are supported by
the DSE global tech nical support
team which gives our customers
and end users access to 24 hour
system help and advice.
KEY BENEFITS
• Ultimate size to feature ratio
• Automatically transfers between
mains (utility) and generator
(DSE4520 only)
• Hours counter provides accurate
information for monitoring and
maintenance periods
• User-friendly set-up and button
layout for ease of use
• Multiple parameters are
monitored simultaneously which
are clearly displayed on the
largest back-lit icon display in
its class
• The module can be configured
to suit a wide range of
applications
• Uses DSE Configuration Suite
PC Software for simplified
configuration
• Compatible with a wide range
of CAN engines
• Licence-free PC software
• IP65 rating (with optional
gasket) offers increased
resistance to water ingress
KEY FEATURES
• Alternator frequency & CAN
speed sensing in one variant
• Largest back-lit icon display in
its class
• Heated display option
• Real time clock provides
accurate event logging
• Fully configurable via the fascia
or PC using USB
communication
• Extremely efficient power save
mode
• 3 phase generator sensing
• 3 phase mains (utility) sensing
(DSE4520 only)
• Compatible with 600 V ph to ph
nominal systems
• Generator/load power
monitoring (kW, kV A, kV Ar, pf)
• Accumulated power monitoring
(kW h, kVA h, kVAr h)
• Generator overload protection
(kW)
• Generator/load current
monitoring and protection
• Fuel and start outputs
(configurable when using CAN)
• 4 configurable DC outputs (2 for
DSE4510)
• 3 configurable analogue/digital
inputs
• 4 configurable digital inputs
• Configurable staged loading
outputs
• 3 engine maintainance alarms
• Engine speed protection
• Engine hours counter
• Engine pre-heat
• Engine run-time scheduler
• Engine idle control for starting &
stopping
• Battery voltage monitoring
• Start on low battery voltage
• Configurable remote start input
• 1 alternative configuration
• Comprehensive warning,
electrical trip or shutdown
protection upon fault condition
• LCD alarm indication
• Event log (50)
SPECIFICATION
DC SUPPLY
CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
CRANKING DROPOUTS
Able to survive 0 V for 50 mS, providing
supply was at least 10 V before dropout and
supply recovers to 5 V. This is achieved
without the need for internal batteries.
LEDs and backlight will not be maintained
during cranking.
MAXIMUM OPERATING CURRENT
85 mA at 12 V, 96 mA at 24 V
MAXIMUM STANDBY CURRENT
51 mA at 12 V, 47 mA at 24 V
MAXIMUM SLEEP CURRENT
35 mA at 12 V, 32 mA at 24 V
MAXIMUM DEEP SLEEP CURRENT
<10 uA at 12 V, <10 uA at 24 V
MAINS (UTILITY) DSE4520 ONLY
VOLTAGE RANGE
15 V to 415 V AC (Ph to N)
26 V to 719 V AC (Ph to Ph)
FREQUENCY RANGE
3.5 Hz to 75 Hz
OUTPUTS
OUTPUT A (FUEL)
10 A short term, 5 A continuous,
at supply voltage
OUTPUT B (START)
10 A short term, 5 A continuous,
at supply voltage
AUXILIARY OUTPUTS C & D
2 A DC at supply voltage
AUXILIARY OUTPUTS E & F DSE4520
2 A DC at supply voltage
GENERATOR
VOLTAGE RANGE
15 V to 415 V AC (Ph to N)
26 V to 719 V AC (Ph to Ph)
FREQUENCY RANGE
3.5 Hz to 75 Hz
DIMENSIONS
OVERALL
140 mm x 113 mm x 43 mm
5.5’’ x 4.4” x 1.7”
PANEL CUT-OUT
118 mm x 92 mm
4.6’’ x 3.6”
MAXIMUM PANEL THICKNESS
8 mm
0.3”
STORAGE TEMPERATURE RANGE
-40 °C to +85 °C
-40 °F to +185 °F
OPERATING TEMPERATURE RANGE
-30 °C to +70 °C
-22 °F to +158 °F
-40 °C to +70 °C (for heated display variant)
-40 °F to +158 °F (for heated display variant)
ENVIRONMENTAL TESTING STANDARDS
ELECTRO-MAGNETIC COMPATIBILITY
BS EN 61000-6-2
EMC Generic Immunity Standard for
the Industrial Environment
BS EN 61000-6-4
EMC Generic Emission Standard for
the Industrial Environment
ELECTRICAL SAFETY
BS EN 60950
Safety of Information Technology Equipment,
including Electrical Business Equipment
TEMPERATURE
BS EN 60068-2-1
Ab/Ae Cold Test -30 oC
BS EN 60068-2-2
Bb/Be Dry Heat +70 oC
VIBRATION
BS EN 60068-2-6
Ten sweeps in each of three
major axes
5 Hz to 8 Hz at +/-7.5 mm,
8 Hz to 500 Hz at 2 gn
HUMIDITY
BS EN 60068-2-30
Db Damp Heat Cyclic 20/55 oC
at 95% RH 48 Hours
BS EN 60068-2-78
Cab Damp Heat Static 40 oC
at 93% RH 48 Hours
SHOCK
BS EN 60068-2-27
Three shocks in each of three major axes
15 gn in 11 mS
DEGREES OF PROTECTION
PROVIDED BY ENCLOSURES
BS EN 60529
IP65 - Front of module when installed into the
control panel with the optional sealing gasket.